India |
Please fill in the following.
Position : Production Supervisor (GGS) Job Profile:
8-10 yrs of experience in Oil & Gas plant mainly Gas separation , gas treatment with good exposure in commissioning , start up , shut down of natural gas processing plant .
Name :
Email :
Contact no :
Alternative Phone no :
D.O.B :
Maximum Qualification :
Total Experience :
 
Current Annual Salary :
 
Expected Annual Salary :
 
Current Location :
Country :
Gender : Male   Female
Attach Resume :
Attach passport size photo :
Question 1: In Glycol Dehydration unit have you ever worked with energy exchange pump? Especially with Kimray Glycol pumps which run on Glycol pressure? If yes where and what is your experience with those pumps?
Answer : Character limit 160.
Question 2: Would you prefer Ground flare system or Elevated flare system? Give reasons why?
Answer : Character limit 160.
Question 3: What is the method by which you detect Gas leakage in Gas processing unit? Have you ever used laser technology to detect methane?
Answer : Character limit 160.
Question 4: In Gas processing plant we use High Pressure separator and Low pressure separator, what is the role of low pressure separator?
Answer : Character limit 160.
Question 5: Have you ever worked in a plant which does not have Emergency Shutdown System?
Answer : Character limit 160.
Question 6: Whether you will prefer orifice or ultrasonic meter for metering of sale gas?
Answer : Character limit 160.
Question 7: In case of shutdown of plant what is the mode of communication between Seller, Gas transporter and the end customer?
Answer : Character limit 160.
Question 8: Have you ever worked on Neuflo scanner and whether you can calibrate the same?
Answer : Character limit 160.
Question 9: Whether you would prefer SCADA/PLC or manual system for gas processing plant?
Answer : Character limit 160.
Question 10: Where is the relief valve located and in the 3-phase separator how to set the same?
Answer : Character limit 160.
Question 11: Are you familiar with Fisher and Kimray valves?
Answer : Character limit 160.
Question 12: Would you be able to change the controller of pressure control valve and is it possible to replace proportional controller with Positioner (I/P) controlled valve? Which one do you prefer proportional controller or I/P controller?
Answer : Character limit 160.
Question 13: What is your experience with difference pressure gauge at basket strainer and what does it tell you and what remedial steps you will take?
Answer : Character limit 160.
Question 14: What is the difference between MEG and TEG?
Answer : Character limit 160.

 

Home   |   Projects   |   News Paper Ads   |   Langtala   |   Vendor Registration   |   DashBoard